Re: Falmouth Wind II Turbine Relocation Study 

Author:  | Massachusetts, Noise, Siting

This letter (PDF attached) is respectfully submitted to the Town of Falmouth to provide a qualified professional opinion about the proposed relocation of Wind II. This is submitted independently as a courtesy to the Town free of compensation from any party.

The original permittings for Wind I and Wind II (and NOTUS) resulted in neighbor complaints soon after start-up and were confirmed to exceed Falmouth’s 40-dBA noise limit (turbines sited too close). Weston & Sampson’s relocation recommendation for Wind II appears to be inconsistent with the Town 40 dBA noise limit and the 2017 Barnstable Superior Court Decision.

1. The distance to meet 40 dBA for Wind II, a Vestas V82 with sound power level of 110 dBA, is approximately 891 meters or 2923 feet. This is greater than the setback distances provided by the proposed new location. The proposed new location is still too close.

2. At 2147 and 2244 feet listed in the subject report, the expected sound level is 43 dBA.

3. Use of the proposed new location appears certain to result in the relocated wind turbine’s maximum noise levels exceeding the Falmouth noise limit of 40 dBA.

4. Use of the proposed new location appears certain to result in the relocated wind turbine’s maximum noise levels exceeding established background sound levels of 27-28 dBA by over 10 dB, breaching State 10-dB noise limits.

Supporting detail is provided in the attached PDF. Please contact me if you have any questions.

Respectfully Submitted,
Robert W. Rand, ASA, INCE

October 26, 2018


Robert W. Rand, Member ASA, INCE
Rand Acoustics
Tel: 207-632-1215
Fax: 206-339-3441
Web: http://randacoustics.com

TO:
Mr. Julian M. Suso, Town Manager
Mr. Rod Palmer, Building Commissioner
Town of Falmouth
59 Town Hall Square
Falmouth, MA 02540

Re: Wind Turbine Relocation Study, Weston & Sampson Report, October 12, 2018

Download original document: “Re: Wind Turbine Relocation Study

This material is the work of the author(s) indicated. Any opinions expressed in it are not necessarily those of National Wind Watch.

The copyright of this material resides with the author(s). As part of its noncommercial educational effort to present the environmental, social, scientific, and economic issues of large-scale wind power development to a global audience seeking such information, National Wind Watch endeavors to observe “fair use” as provided for in section 107 of U.S. Copyright Law and similar “fair dealing” provisions of the copyright laws of other nations. Queries e-mail.

Wind Watch relies entirely
on User Funding
   Donate via Paypal
(via Paypal)
Donate via Stripe
(via Stripe)

Share:

e-mail X FB LI TG TG Share

Get the Facts
CONTACT DONATE PRIVACY ABOUT SEARCH
© National Wind Watch, Inc.
Use of copyrighted material adheres to Fair Use.
"Wind Watch" is a registered trademark.

 Follow:

Wind Watch on X Wind Watch on Facebook

Wind Watch on Linked In Wind Watch on Mastodon